Olympus-OM
[Top] [All Lists]

Re: [OM] Help: Odd behavior from MD1

Subject: Re: [OM] Help: Odd behavior from MD1
From: "Hans van Veluwen" <hcvanveluwen@xxxxxxxxx>
Date: Sat, 24 Mar 2001 12:58:32 +0100
:I installed NiMH batteries in an old 15V Control Pack and everything worked
:fine after I got it back together.  Now, however, when I put the Control Pack
:on an MD1 and turn it on, either in single of continuous mode, it starts
:shooting continuously.

This probably means that the tuning ('re-timing'), as explained in the repair
FAQ, isn't done properly or that the centre post which is used for this tuning
wasn't tightened enough and has come loose.

hnz



< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >