Or use a scuba tank.
tOM
On Sunday, March 14, 2004 at 17:08,
Mark Dapoz <olympus@xxxxxxxxxx> wrote:
>
> On Sun, 14 Mar 2004, Donald MacDonald wrote:
> >
> > Mark, thanks very much for your reply, I'll be taking your advice on
> > board. I know next to nothing about this, so I'm learning all the time.
> > The compressor I'm looking at is electrical, 1.5hp, 24 litre tank, oil
> > free. I was thinking of a filter/regulator; you'd fit two?
>
> I'd use two filters, one regulator is enough though. The main concern is
> water, you don't want it coming out in the air stream. With small single
> stage compressors such as the one you're looking at, the air gets *very*
> hot as it's compressed. This allows the air to hold more moisture which
> then causes water droplets to form as it's released from the end of the hose.
> Two good filters/water traps should be enough to keep the air dry.
>
> > I got to thinking about photographic uses after deciding a nailer was in
> > my future. Much more practical for ramming home those 50mm brads...
>
> It's probably easier to justify the nailer than the glorified OM duster :-)
> It sure beats those cans of compressed air though!
> -mark
>
>
> The olympus mailinglist olympus@xxxxxxxxxx
> To unsubscribe: mailto:olympus-request@xxxxxxxxxx?subject=unsubscribe
>
> To contact the list admins: mailto:olympusadmins@xxxxxxxxxx?subject="Olympus
> List Problem"
>
------- Quidquid latine dictum sit altum viditur -------
,__@ tOM Trottier +1 613 231-6115
_-\_<, 758 Albert St.,Ottawa ON Canada K1R 7V8
(*)/'(*) N45.412 W75.714
<a href="http://Abacurial.com">Abacurial Information Architecture</a>
---------------
I would rather be exposed to the inconveniences attending too
much liberty than to those attending too small a degree of it.
-Thomas Jefferson 1743-1826)
The olympus mailinglist olympus@xxxxxxxxxx
To unsubscribe: mailto:olympus-request@xxxxxxxxxx?subject=unsubscribe
To contact the list admins: mailto:olympusadmins@xxxxxxxxxx?subject="Olympus
List Problem"
|