Erratic auto exposure (especially after water damage) could be caused by a
dirty / corroded ceramic resistor board which encircles the top of the
meter, just under the top cover.
John Hermanson
Camtech Photo Services, Inc.
21 South Lane, Huntington, NY, 11743-4714,
631-424-2121, www.zuiko.com
Olympus OM Service since 1977
<:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:-:>
----- Original Message -----
From: "Fernando Gonzalez Gentile" <fgnzalez@xxxxxxxxxxxxx>
To: <olympus@xxxxxxxxxx>
Sent: Wednesday, April 13, 2005 6:11 PM
Subject: [OM] Re: Digital, digital, digital. Bah, humbug!
> Well since you asked, I had to think it over, and looked up into some
> updated bibliography this afternoon, while waiting for a diagnosis on what
> ails my sobbing OM-2.
>
> I think this one to be a typical case of 21st century schizoid man, since
> it
> fulfills criterion A of the renowned DSMIVR:
>
>>1) A: ...nothing he's got, he really needs.
>
> ;^)
>
> Fernando.
>
> on 13/04/2005 15:51, Piers Hemy at piers@xxxxxxxx, wrote:
>
>> You mean . . . it's just a regular psychosis?!
>
==============================================