Olympus-OM
[Top] [All Lists]

Re: [OM] OM1

Subject: Re: [OM] OM1
From: "Terry and Tracey" <foxcroft@xxxxxxxxxxxxxxxxxxxxxx>
Date: Mon, 14 Feb 2000 21:57:47 +1100
It is the problem. Go mercury, or get it modified for a silver oxide cell.
Alkaline cell voltage drops with time, the other two stay flat.

OM-1 does not use a bridge circuit in it's metering, so it relies on  the
battery voltage remaining constant.

Foxy

----- Original Message -----

> Having read recent threads about OM1's and meter readings, its rather
ironic
> that I seem to have the same problem myself, in so far as my OM1 seems to
be
> under reading by at least two stops.
>
> The battery is a PX625A, Alkaline Cell, made in China, inserted by the
> previous owner. Clutching at straws, could this be the problem? If it
isn't,
> any other suggestions?
>
> Paul Reynolds



< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >


<Prev in Thread] Current Thread [Next in Thread>