There's always left-over oil inside the ring that the blades sit on.
Only fix is to completely disassemble, remove blades, clean everything
with degreaser and rebuild. Then disaasemble focus helicoid, degrease
all parts, apply proper grease and rebuild, reset infinity focus.
___________________________________
John Hermanson | CPS, Inc.
21 South Ln., Huntington NY 11743
www.zuiko.com | omtech1@xxxxxxxxxxx
Olympus OM Service since 1977
On 11/29/2014 11:32 PM, Moose wrote:
On 11/29/2014 8:09 PM, Chuck Norcutt wrote:
Ah, but there is more than one way to skin a cat.
I tried this method on a sticky aperture (50/1.8?) Perhaps I didn't
rinse enough times. Perhaps there was just too much loose oil that
filled the void. The problem returned all too soon.
Stuck Together Moose
--