Hi, Doug,

Voltage on the high lines varies from system to system.  At the research 
center where I worked before retiring, the main facility feeds were 161,000 
volts, run underground.  The so-called "housekeeping" circuits were 13,800 
volts, 3-phase, run overhead.  At one time I asked what the 3-phase lines 
that run past my house were, but I have forgotten the answer.  I suspect 
they are around 10k to 12k volts.  Those are the shielded lines in the 
photos.

I agree that, handled one at a time while in an insulated bucket, the risk 
is lessened.  However, on a damp day, I would at least use well-insulated 
gloves which can be found in a lineman's kit.

Jim Nichols
Tullahoma, TN USA
----- Original Message ----- 
From: "Doug" <doug9345@xxxxxxxxxxxx>
To: "Olympus Camera Discussion" <olympus@xxxxxxxxxxxxxxxxx>
Sent: Thursday, December 18, 2008 8:30 PM
Subject: Re: [OM] IMG: Even in Dismal Weather, the Work Must Go On


> On Thursday, December 18, 2008 12:55, Jim Nichols wrote:
>> Thanks for looking, Chuck.  I did not see it done, but suspect it was
>> handled with a "hot stick" to insulate the workman.  They are very much
>> aware of the dangers involved.
>>
>
> I watched and talked to the linemen when they replaced the pole in my 
> front
> yard(planned upgrade). The line looks similar to the set up in the photo,
> except that it's only two wires and not three. I'm far enough out in the
> country that they only run a single phase down the road. I asked what the
> voltage was on the wires and the man I was talking to told me that it was
> 9200 volts between the lines, 4600 volts to ground.  They moved the lines
> from one pole to the next by simply taking ahold of them one at a time and
> moving them to the new pole. The rubber insulation was used when they 
> where
> hooking up the new transformer so that they wouldn't  end up handling one 
> of
> the lines or ground and at the same time backing into the other wire. What
> one member of the crew told me was that their boom was tested every three
> months at 150k volts.
>
> -- 
> _________________________________________________________________
> Options: http://lists.thomasclausen.net/mailman/listinfo/olympus
> Archives: http://lists.thomasclausen.net/mailman/private/olympus/
> Themed Olympus Photo Exhibition: http://www.tope.nl/
>
> 


-- 
_________________________________________________________________
Options: http://lists.thomasclausen.net/mailman/listinfo/olympus
Archives: http://lists.thomasclausen.net/mailman/private/olympus/
Themed Olympus Photo Exhibition: http://www.tope.nl/

<Prev in Thread] Current Thread [Next in Thread>
Sponsored by Tako
Impressum | Datenschutz