> The spacers and standoff bushings are self centering, they support each
> other as the screw is tightened. No other work, tapping, screwing
> required. As stamping is drilled out, you hold camera upside down so
> flakes fall out of camera, then inspect with a loupe. Check cams on large
> gear stack, lube lightly with molylube.
>
> John Hermanson
> Camtech Photo Services, Inc.
> 21 South Lane, Huntington, NY 11743
> 631-424-2121 | omtech@xxxxxxxxx
> www.zuiko.com
> Factory Trained OM Service since 1977
> __________________________________
> ----- Original Message -----
> From: <bartjew@xxxxxxxxx>
> To: <olympus@xxxxxxxxxx>
> Sent: Thursday, November 10, 2005 9:18 AM
> Subject: [OM] Re: OM2 Spot/Program shutter etc problem
>
>
>>
>> Hi John,
>>
>> Just to satisfy my curiosity:
>> How do you fix them after having drilled off the flange? Tap a thread
>> and use a screw? Won't it come loose by the movement of the underlying
>> lever?
>> How to protect the internals from the grindings?
>> After degreasing, do you apply any form of lubricant to the parts, or do
>> you put them back in dry?
>>
>> Thanks,
>> Bart
>>
>>
>> Citeren John Hermanson <omtech@xxxxxxxxx>:
>>
>>>
>>> The greasy levers have to be degreased but Oly designers thought it
>>> would
>>> speed production by stamping that assembly shut. You can drill out
>>> uppermost lip of stamping (directly under big screw) with 7/64" drill,
>>> then
>>>
>>> greasy levers will come out easily.
>>>
>>> John Hermanson
>>> Camtech Photo Services, Inc.
>>> 21 South Lane, Huntington, NY 11743
>>> 631-424-2121 | omtech@xxxxxxxxx
>>> www.zuiko.com
>>> Factory Trained OM Service since 1977
>>> __________________________________
>
==============================================