On Mon, 27 Jan 2003, Andrew Gullen wrote:
> Thanks, Mark(s). I am fairly handy and meticulous at this kind of thing,
> though I may want to keep the Hermanson option open, especially as once I
> disassemble it my return options disappear.
I know this is obvious, and you probably already know this, but do NOT work on
the flash heads while connected to the T-Power! There are several kV of power
present when the flash is fired and it can give you quite a jolt. If you do
find the contacts are oxidised and/or corroded, the only real fix is to replace
the contacts, not just clean them. The high voltage running though them will
likely cause the problem to re-appear.
-mark
< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >
|