The spring that rides the detent is pushed down over plastic studs, the then
studs are melted down to hold the spring. Not so good for longevity. Take
the knob area apart, trim the plastic studs off the switch, drill out and
install 2mm screws.
John Hermanson
___________________________________
Camtech, Olympus Service since 1977.
21 South Lane, Huntington NY 11743-4714
631-424-2121 http://www.zuiko.com
Free Olympus Manuals: 1-800-221-3000
___________________________________
----- Original Message -----
From: <RobBurn@xxxxxxx>
To: <olympus@xxxxxxxxxxxxxxx>
Sent: Thursday, August 24, 2000 8:59 PM
Subject: [OM] Another HELP request
| Is there a simple way to increase the friction on the battery test, auto,
| off,
| self-timer ring on an OM-10? I have one so loose it inadvertently gets
turned
| on/off quite frequently.
|
| Thanks,
|
| Robert
|