Or, the manual circuit board behind the coupling rings is dirty. This is a
thin ceramic board with small resistors and sliding brushes. The brushes
are pulled in either direction by strings sttached to the ss ring.
John
----------------------------------------------------------------
Camtech / Olympus Service since 1977
21 South La., Huntington NY 11743-4714
516-424-2121 http://www.zuiko.com
--------------------------------------------------------------
----- Original Message -----
From: <HI100@xxxxxxx>
To: <olympus@xxxxxxxxxxxxxxx>
Sent: Wednesday, September 15, 1999 11:29 PM
Subject: Re: [OM] OM-2 Light Meter
> Jimmy,
> your OM2 should work first time on whatever it is switched to.
> Sounds like a dirty or damaged mode selector switch. The match needle
meter
> circuit is not very complex containing only resistive components, so I
would
> strongly suspect the switch.
>
> Tim Hughes
> Hi100@xxxxxxx
>
> < This message was delivered via the Olympus Mailing List >
> < For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
> < Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >
>
>
< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >
|