Ivan Balcacanovic wrote:
> All I ask is some technical information about OM20
OM-20
SLR with auto exposure (aperture priority) and manual exposure (set
aperture and shutter speed independ of each other).
Shutter times in auto mode 1/1000-2sec and in manual mode 1/1000-1sec.
At "B" the shutter will stay open as long as the trigger is pressed (or
the batteries are exhausted).
Auto mode works with ADM metering and automatic syncronisation if an
dedicated flash is used, there is no TTL control of the flash.
You can connect an motor or winder to the body.
The OM-20 needs two silveroxid cells (SR44) to operate, use no lithium
cells, alkaline cells will work only for a short time (not economical).
Regards
Richard
< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >
|